  power measuring instruments wide spectrum power meter for comprehensive device assessment dc/0.5hz to 1mhz broad-band power hitester measures up to 6 systems simultaneously. 3193 power hitester the 3193 power hitester is a multi-function power meter for use with single phase power lines to 3-phase, 4-wire circuits. accommodating up to 6 units, it is not only capable of measuring up to 6 single phase systems, but can simultaneously measure the input and output of a 3-phase inverter and provide effective power measurements. additionally, it supports harmonic analysis and flicker measurement (optional), features which are essential for overall device assessment. standard features include a gp-ib/rs-232c interface and 3.5-inch floppy disk drive, making it easy to feed data to a personal computer for processing and analysis. this unit is ideal for those requiring greater efficiency in electrical device assessment. printer is optional unit 3194 motor / harmonic hitester 3194 motor / harmonic hitester provides analysis of high-order harmonics up to the 3000th order. additionally, with the optional 9603-01 external signal input unit installed, the hitester can directly measure torque and rotation speed, an essential feature for evaluating the performance of inverter motors. this makes it easy to construct measurement systems.
harmonic and flicker analysis harmonic and flicker analysis are possible when using the optional 9605 harmonic / flicker measurements unit (3193 only) . a variety of interfaces for differing needs connecting to a pc the 3.5 inch floppy disk drive and rs-232c / gp-ib interface, provided as standard features, make it possible to connect the power meter directly to a pc, allowing efficient measurement, management and analysis of data. connecting to a printer data can be output to the optional 9604 printer unit . : thermal line dot printing : 72mm : printing of items measured, hard copy output of displayed screens, printout of meter settings, printout of various times (such as interval time, timer time, and realtime control time). printouts are performed either automatically, upon input of an external control signal, or synchronized with an integrator. print type paper width main functions can measure motor output with the optional 9603 external signal input unit , the hitester can take analog input in from torque and revolution measurements and use that information to calculate motor output. high visibility color lcd featuring a wide viewing angle, the color lcd displays a variety of items simultaneously, making it ideal for quickly grasping power usage on the system being measured. expanded display is possible for any four selected items. 1 complete with functions that answer broad coverage, high accuracy, and well-developed interface features wide range of measurement functions capable of measuring voltage, current, active /reactive /apparent power, power factor, phase, frequency, and current, and of integrating power according to polarity, the 3193 ( or 3194 ) also provides wave peak and efficiency measurements that are essential to device assessment. high basic accuracy of 0.2% measurements of even greater precision can be obtained using the optional 9600 to 9602 input unit, which provides a basic accuracy of 0.1% rdg,0.1% f.s. (with the 9602, the accuracy of the clamp-on sensor is a factor affecting total accuracy during power measurement.) measurement for minute stand-by power also available (by special-order product) the 9600 and 9601 input units have 10-times improved current sensitivity, and currents starting from the 20.000ma range can be measured. (please ask for further information.) connecting to a recorder with 8 selectable d/a outputs and voltage, current and power analog/ monitor output (current and voltage only) as standard features, the hitester allows recording of changes and transient fluctuations in waveforms using a recording unit. enlarged indication all your power measurement needs.
2 9600 dc/0.5hz to 1mhz wide band 9601 5hz to 100khz, for ac only 9602 dc/0.5hz to 200khz clamp input a variety of clamp on sensors are available, including models 9270 to 9272 for ac only, and models 9277 to 9279 for ac/dc. simultaneous measurement of multiple systems since all units are mutually isolated, the primary and secondary sides of devices or disparate power lines can be measured simultaneously. simultaneous measurement of single phase 6 wire or 3 phase 2 wire systems which previously required multiple units, can now be handled with one. what's more, measurements of all devices can be taken at the same instant, providing a powerful tool for integrated, all-round device assessment. choose from a variety of input units according to application three types of input units are available, including the 9602 clamp input meter, which can be used with current levels exceeding 50a under live circuit conditions, as well as the 9600 and 9601 which accept direct input of up to 1000v/50a. 1ch 2ch 3ch 4ch 5ch 6ch 1 ?2 w 1 ? 2w 1 ? 2w 1 ? 2w 1 ? 2w 1 ? 2w 1 ? 3w / 3 ? 3w 1 ? 2w 1 ? 2w 1 ? 2w 1 ? 2w 1 ? 3w / 3 ? 3w 1 ? 3w / 3 ? 3w 1 ? 2w 1 ? 2w 1 ? 3w / 3 ? 3w 1 ? 3w / 3 ? 3w 1 ? 3w / 3 ? 3w 3v3a (3 ? 3w) / 3 ? 4w 1 ? 2w 1 ? 2w 3v3a (3 ? 3w) / 3 ? 4w 3v3a (3 ? 3w) / 3 ? 4w 3v3a (3 ? 3w) / 3 ? 4w 1 ? 3w / 3 ? 3w 1 ? 2w 1 ? 2w 9600 frequency characteristics (at 15 w [15v ? 1a] range, response slow) effect of common mode voltage frequency (hz) frequency (hz) error (%) influence (%) peak measurements function voltage and current wave peaks can be measured. the peak hold function can be used to find peak values and effective max imu ms f o r mo to r r u s h current waves. integration according to polarity positive, negative, and total c u r r e n t a n d p o w e r c a n b e integrated simultaneously for all channels. this makes it possible to grasp the income and outflow of power at a glance. wave monitor outpu t provides analog and d/a output. with the voltage and current ranges, waveforms are output a s 1 v f u l l s c a l e v a l u e s , allowing waveforms to be monitored using devices such as recorders or synchroscopes. analog (voltage, current, and e ff e c t i v e p o w e r ) a n d d / a outputs (any selected eight items) are output as a 5v range full scale value. (except for the 1000v range), 100ms response time can be obtained by using the fast setting. 3 types of averaging function select from time average, moving average and exponential average. 3ch frequency measurement function with the frequency ranges, lpf and hpf can be used in combination, allowing measurement of fundamental waveforms and carrier waveforms of inverters. efficiency calculation function three efficiency calculations can be obtained simultaneously from measured voltage values. 3 types of built-in low pass filters selectable cutoff frequencies (500/5k/300khz) allow extraction of the frequency component of fundamental inverter waveforms and provide data compatibility with previous instruments. choose from three types of calculation algorithms three selectable algorithms are provided for calculating apparent power and reactive power, providing compatibility with previous devices input wave active power analog output active power d/a output 100ms 20 s input wave 50khz pulse voltage monitor output current monitor output 60hz, sinwave peak value other analysis functions
3 example of application with power converter measure mixed ac and dc components with a single unit. example of assessment trial of ev ( electric vehicle ) the power analysis station can measure all items at same point in time applications of 3193 1, 3, 4ch ac u /i /p, primary to secondary efficiency 2, 5 ch monitoring of dc u /i /p after dc/ac 3ch u /i /p s eparate charge / generation integration wh 1, 2 ch 3 phase after dc/ac, ac u /i /p /wh separate charge/generation integration capability. measurement under live circuit conditions. (clamp input) 3194 performs comprehensive evaluation of 3-phase inverter motors 1, 2, 3 ch (primary) v/a/w/pf, harmonic analysis capable of measuring carrier frequencies on the secondary side of inverters. also allows analysis to be synchronized with motor rotation. 4, 5, 6 ch (secondary) v/a/w/pf and motor output, efficiency, harmonic analysis harmonic analysis to the 3000th order fundamental frequency sampling speed (hz) window width analysis order pll synchronization ranges 10 - 17.5 hz f 8192 1 waveform 3000 ( 10khz or less) 17.5 - 35 hz f 8192 1 waveform 3000 ( 10khz or less) 35 - 70 hz f 8192 1 waveform 3000 (100khz or less) 70 - 140 hz f 4096 2 waveforms 1500 (100khz or less) 140 - 280 hz f 2048 4 waveforms 800 (100khz or less) 280 - 560 hz f 1024 8 waveforms 400 (100khz or less) 560 - 1120 hz f 512 16 waveforms 200 (100khz or less) 1120 - 2240 hz f 256 32 waveforms 100 (100khz or less) 2240 - 4500 hz f 128 64 waveforms 50 (100khz or less) fixed clock ---- 50 8192 fixed 2 waveforms 3000 (100khz or less) : single-phase 2- and 3- wire, three-phase 3- and 4-wire : up to 3 channels from channels 1 to 6 : fundamental frequency: 10 hz to 4.5 khz : pll or external clock : 12 bits : rectangular tiling (with gap between windows) : up to 2.5 (voltage, current) : u, i or external synchronization : input to a rear panel control terminal on the 3194 main unit input level: 1v to 10 vrms, division function: 1/1 to 1/255 : rms voltage, rms current, effective power value, frequency, u peak, i peak : harmonic level, percentage and phase angle of harmonic wave, total harmonic distortion (thd-f, thd-r) : list, graph, vector and waveform displays : -y voltage conversion, y- voltage conversion : s orts according to decreasing order of analysis, displays up to 50th order : index average with time constant of 1.5 sec measurement lines no. of channels measurement range measurement method a/d resolution windowing type crest factor pll source ext. synchronization signal measurement items harmonic wave measurement items screen displays wiring conversion sort function averaging function harmonic waveform analysis functions 3194 specifications (harmonic waveform analysis function) frequency ranges : note 1: analysis order accuracy is restricted to the frequency in brackets. note 2: with pll synchronization in the range of 10 to 35 hz, an anti-aliasing filter of about 15 khz is used, and with pll synchronization in the range of 35 hz to 4.5khz, an anti-aliasing filter of about 120 khz is used. : 2 channels : strain gauge sensor or dc voltage input (bnc) : pulse or dc voltage input (bnc) : strain gauge type converter (bridge resistance 350 - 1.5k ) : 1 mv/v / 1.5 mv/v / 2 mv/v : 0.1%rdg. 0.065%f.s. : prc03-23a10-7f (manufactured by tajimi) : 200k 5% (differential) : 1.0000 / 5.0000 / 10.000v : 0.1%rdg. 0.1%f.s. (23?c 5?c, not higher than 80%rh) : 1hz to 100 khz : 5v f.s. (output accuracy : measurement accuracy 0.2%f.s) input channels ch a ch b applicable converter measurement range measurement accuracy connector input resistance measurement range measurement accuracy frequency measurement analog output strain gauge input specifications (dedicated connector) dc voltage input specifications (ch a / ch b common bnc connector) common specifications pulse input specifications (ch b, bnc connector) 9603 -01 specifications torque, rotation speed, and motor power can be measured by inputting analog torque and r/m signals to the 9603-01 external input unit . further, an input terminal is provided for use with a strain gauge-type torque sensor . 9603-01 external input unit
4 graph display of harmonics voltage, current and power can be analyzed and displayed b y b a rg r a p h s o f h a r m o n i c amplitude, content and phase angle.voltage, current and power can be displayed simultaneously for a single channel, or a single parameter can be displayed simultaneously for each of three channels. waveform display the waveform display shows one cycle of the voltage and current waveforms. rms and peak values can be displayed along with voltage and current waveforms, or voltage and current waveforms for up to three channels can be displayed at the same time. list display of harmonics t h e h a r m o n i c l i s t d i s p l a y shows the amplitude, pro- p o r t i o n , p h a s e a n g l e a n d distortion for each harmonic of voltage, current and power. displaying only proportion, o r t w o p a r a m e t e r s s i m u l - taneously, such as amplitude and phase angle, is selectable. vector display of harmonics the harmonic vector display shows the voltage, current and phase angle for each harmonic, m a k i n g c l e a r t h e v o l t a g e - current phase relationship. support up to harmonic / flicker analysis when using the optional 9605 harmonic / flicker measurements unit . monitor display the relative "d" voltage change ?v/v and the instantaneous flicker value "s(t)" can be displayed in a time series, so past variations are clearly displayed. flicker measurement display displays data during measurement in real-time. display can also be switched to d measurement and "pst" value. : installs in the 3193 main unit : single-phase 2- and 3-wire, three-phase 4-wire : up to 3 channels within channels 1 to 6, depending on 3193 wiring mode : floppy disk, rs-232c, gp-ib, printer : fundamental frequency: 1 to 440 hz pll system (5 to 440 hz ) , external clock system (1 to 5 hz) : up to 50th harmonic (with 1 to 250 hz fundamental) : 16 cycles (for 40 to 70 hz fundamental) : rectangular tiling (no gap between or overlap of windows) : 512 points (for 40 to 70 hz fundamental) : up to 4 (current), and up to 3 (voltage) : harmonic level, percentage and phase angle of each order of harmonic wave for each of voltage, current and power. total up to 50th harmonic (of 40 to 70 hz fundamental) for voltage, current and power. total harmonic distortion for voltage and current (thd-f and thd-r) measurement of voltage, current, active power, peak voltage and peak current values of the fundamental installation measurement lines no. of channels output functions measurement range orders analyzed window width windowing type amount of data analyzed crest factor measurement items : every 1 window (except during communications with other devices) : list, graph, vector and waveform : harmonic levels; at 45 to 66 hz voltage/current: 0.5%rdg.0.05% f.s. active power: 1.0%rdg. 0.1% f.s. for 45 to 66-hz fundamental, effective input is 0.1 to 110% of range, total error of harmonic current when pll is locked is 5% of the limit value or within 0.2% of the rated current of the device under test (no limitation with 9602). : fundamental frequency; 45 to 66 hz, pll synchronization system : dc (relative constant voltage change), d max (max. relative constant voltage change), d(t)200ms (relative voltage change per time), p0.1/ p1s/ p3s/ p10s and 30s (cumulative probability), pst (short-term flicker value), plt (long-term flicker value) : measured value, cpf, pst list, monitor : within 5% rdg. of limit on the limit curve line (pst = 1) specified for voltage fluctuation in iec60868-0 (d measurement is the same) rms voltage 0.5%rdg . 0.05%f.s. (45hz ~ 66hz) update rate screen displays accuracy* 3 measurement range analysis items screen displays accuracy* 3 flicker measurement function (iec61000-3-3 * 2 ) harmonic waveform analysis functions (iec61000-3-2 * 1 ) *2. decision function not included. *3. the reading accuracy of the input unit must combined with the analysis accuracy shown above. when used with a clamp sensor, accuracy and frequency characteristics of the clamp must be added to the analysis accuracy above. 9605 specifications (optiona l ) *1. the 9605 does not support limit values, so pass/fail decisions based on limit values, classification of special waveforms (a to d) and 2.5-minute measurement function for measuring transient harmonic currents are not supported. applications of 3193
5 optional input unit specifications 9600 ac/dc direct input unit 9602 ac/dc clamp input unit voltage current active power voltage current active power measurement range 6.0000/15.000/30.000/ 60.000/150.00/300.00/ 600.00v/1.0000 kv 200.00/500.00ma/ 1. 0000/2.0000/5.0000/ 10.000/20.000/50.000 a depends on combination of voltage and current ranges 6.0000/15.000/30.000/ 60.000/150.00/300.00/ 600.00v 500.00ma to 500.00a ( depends on clamp-on sensor) depends on combination of voltage and current ranges max.operating inpu t (55hz ) 1000vrms/1500 v peak 65arms/100 a peak 650vrms/850vpeak (depends on clamp-on sensor) crest factor input resistance 2m?5% 1m max. 2m?5% 200k?5% accuracy 0.5 to 1hz 0.5%rdg.0.5%f.s. 0.5%rdg.0.5%f.s. 1 to 10hz 0.2%rdg.0.2%f.s. 0.2%rdg.0.2%f.s. 10 to 45hz 0.1%rdg.0.2%f.s. 0.1%rdg.0.2%f.s. 45 to 66hz 0.1%rdg.0.1%f.s. 0.1%rdg.0.1%f.s. 66hz to 10khz 0.1%rdg.0.2%f.s. 0.1%rdg.0.2%f.s. 10 k to 50khz 0.3%rdg.0.3%f.s. 0.5%rdg.0.5%f.s. less than 5 a less than 5 a 50 k to 100khz 0.5%rdg.0.5%f.s. 0.5%rdg. 0.5%f.s. 0.5%rdg. 0.5%f.s. 0.5%rdg. 0.5%f.s. 0.3%rdg. 0.5%f.s. 100k to 300khz 0.5%rdg.0.5%f.s. 0.5%rdg. 0.5%f.s. 1.0%rdg. 1.5%f.s. 15%f.s . (up to 200khz) 30%f.s . (up to 200khz) 300k to 400khz 1.5%rdg.0.5%f.s. 1.0%rdg. 0.5%f.s. 1.0%rdg. 2.5%f.s. 400k to 500khz 2.0%rdg.1.0%f.s. 2.0%rdg. 1.0%f.s. 2.0%rdg. 2.5%f.s. 500k to 700khz 10.0%f.s. 10.0%f.s. 15.0%f.s. 700k to 1 mhz 15.0%f.s. 15.0%f.s. 30.0%f.s. greater than 5 a greater than 5 a 2.5%f.s. 5.0%f.s. 5%f.s. 10.0%f.s. dc 0.1%rdg.0.2%f.s. 0.1%rdg.0.2%f.s. 9601 ac direct input unit voltage current active power measurement range 60.000/150.00/300.00/6 00.00v/1.0000 kv 200.00/500.00ma/ 1. 0000/2.0000/5.0000/ 10.000/20.000/50.000 a depends on combination of voltage and current ranges max.operating inpu t (55hz) 1000vrms/1500 v peak 65arms/100 a peak crest factor input resistance 2m?5% 1m max. 10 to 20hz 1.0%f.s. 20 to 45hz 0.1%rdg.0.2%f.s. 45 to 66hz 0.1%rdg.0.1%f.s. 66hz to 5khz 0.1%rdg.0.2%f.s. 5k to 10khz 0.2%rdg.0.4%f.s. 10k to 20khz 1.0%f.s. 20k to 50khz 2.5%f.s. 5 to 10hz 2.5%f.s. note 1: assured accuracy ranges for different response settings are as follows: fast (0.1 sec) to dc and greater than 50 hz, mid (0.8 sec) to dc and greater than 10 hz, slow (5.0 sec) to dc or greater than 0.5 hz note 2: assured accuracy ranges for combined mode measurement are 10 hz or greater for the ac mode, and dc only for the ac+dc mode or dc mode. assured accuracy range for input frequency of the 9600 9272 9279 9601 and 9602 each have assured ranges for input frequency. calculation algorithm (indicated only for single phase, 2 wire and 3 phase, 3 wire (3v3a).t wo additional calculation algorithms can be selected for apparent/reactive power) note 1: the above calculation algorithm is for a single phase, 2 wire input to ch 1, and 3 phase, 3 wire input to ch 1/2/3 (3 voltage, 3 current). note 2: the "s" before each power factor or phase operation indicates the lead or lag of current phase in relation to voltage. the "-" sign means current phase leads voltage and when there is no symbol, it lags. "su" is "-" when the sum of reactive power is negative and "+" (but unsigned) when it is positive. voltage current active power apparent power reactive power power factor phase 1 ? 2w u 1 i 1 p 1 s 1 = u 1 ? i 1 1 = s 1 p 1 /s 1 ? 1 = s 1 co s - 1 1 s u m u 1 2 3 = u 1 + u 2 + u 3 3 i 1 2 3 = i 1 + i 2 + i 3 3 p 1 2 3 = p 1 +p 2 1 2 3 = su p 1 2 3 s 1 2 3 ? 1 2 3 = su co s - 1 1 2 3 3 ? 3w (3v3a) (accuracy assured at 23?c5?c (73?f 9?f) at 80% r.h., power factor = 1, sine wave input, in-phase voltage 0, after dmag) lower of either (measured range ? 6) / measured value or maximum permissible rated peak / measured value lower of either (measured range ? 6)/ measured value or maximum permissible rated peak/measured value with the 9602 , the accuracy of the clamp-on sensor is a factor affecting total accuracy during current measurement, as are phase and frequency characteristics. see page 7 for details on the clamp-on sensor specifications. compatible clamp (optional) 50k to 100khz 10.0%f.s. lower of either (measured range ? 6) / measured value or maximum permissible rated peak / measured value the 9600 and 9601 are also the products for stand-by power measurement with 10-times improved sensitivity for current ranges. please ask for detailed specs. 927 0 9271 927 7 / 9278 9709 accuracy (accuracy assured at 23?c 5?c(73?f 9?f) at 80% r.h., power factor = 1, sine wave input, in-phase voltage 0 ) input voltage (v) input current (a) frequency (hz)
measurement accuracy (23?c5?c (73?f 9?f) , less than 80% rh, warm up time greater than 1 hour, sine wave input, power factor = 1, in-phase voltage = 0) basic specifications measurement method display indication range calculation algorithm calculable factors calculated items number of channels output impedance output items output voltage output update rate compatible media format functions gp-ib rs-232c functions control signal level scaling averaging multilingual display set time (all types) measurement item : digital calculation from measured voltage or pulse signal effective when 9603 ch a is torque (any of n/ m, mn/m, kn/m, kgf/m, kgf/cm), and ch b is r/m : 0.1% to 130% of 9603 voltage range (polarity not indicated) : set to required format : maximum of 3 formats : p for each input unit, pm when combined with 9603 (items measured with 9605 not allowed) : 8ch (12 bit d/a converter polarity + 11bit) : 100?5% : outputs 8 arbitrarily selected items : dc5v/f.s. : 16 times/sec : 3.5-inch, 2hd (1.2mb/1.44mb) : ms-dos : function for saving and loading settings, and saving measured values. function for outputting measured values. floppy disk formatting function, file renaming and deleting : conforms to ieee-488.1 1987, with reference to ieee-488.2 1987 : start-stop synchronous, with baud rate of 2400 or 9600 bits/sec : integration start / stop control, integration data reset, external a/d (for display update when power meter display is in hold mode) , manual print control, fd save control : from 0 / 5v logic signal or short//open contact signal : pt/ct ratio set range 0.0001 to 10000 : time average (set interval time, timer time, and average of realtime control time) moving average (number of samples: 8/16/32/64) exponential average (attenuation factor: 8/16/32/64) : japanese/english screen display switching : interval control time (10 sec to 100 hours) in 10 sec increments ( when used in combination with fdd or printer, auto select increments ) timer control time (1 min to 10000 hours) in 1 minute increments realtime control time, 1 minute increments : see page 4 specifications for 9605 location for use ambient use humidity ambient storage humidity insulation resistance withstand voltage (50/60 hz, 1 minute) : indoors, altitude to 2000 m : power meter, 0?cto 40?c (32?f to 104?f) , rh below 80% (no condensation) when using fdd / printer, 5 ?c to 40 ?c (41?f to 104?f) , rh below 80% : -10 ?c to 50 ?c (14?f to 122?f) , rh below 80% and no condensation : more than 100m from dc500v greater than 50m( at dc500v between u/i input terminal and unit case, between u/i input terminal and power supply plug (for the 9600/9601), between u input terminal and clamp input terminal, between u input terminal and unit case, and between u input terminal and power supply plug (for 9602) : ac5.55kv between u/i terminal and unit case, between u/i terminal and power supply plug (for 9600 and 9601), between u terminal and clamp input terminal, between u terminal and unit case, between u input terminal and power supply plug (for 9602) certifications power supply maximum rated power dimensions, mass accessories : safety en61010-1: 2001 : emc en61326 : 1997+a1 : 1998+a2: 2001 class a e n61000-3-2: 2000 en61000-3-3: 19 95+a1: 2001 : ac100v/120v/200v/230v (switched automatically) , 50/60hz : 150va max. : approx 430 w ? 150 h ? 370 d mm, approx13 kg (approx 16.93 ? (w ) 5.91 ? (h)14.57 ? (d), approx 458.6 oz.) (in configuration including 9600 5 6ch, 9603, 9604) (not including projections such as terminals, feet, and handles) : power cord 1, ground adapter (3p to 2p) 1, connector 1 6 motor output efficiency thermal coefficient effect of in-phase voltage effect of power factor actual time d/a output analog output monitor output : 1dgt for calculations of each measured value : max. 7 dgt with respect to values calculated from measure- ments of items substituted into algorithm : within 0.03% f.s/ ?c : within 0.05% f.s (1000 vrms, 50/60hz, between shorted voltage input terminals and case) : 0.15% f.s (power factor = 0) : 25ppm 1dgt. (0 to 40?c (73?f to 41?f) ) : display accuracy - 0.2% f.s : display accuracy - 0.2% f.s : display accuracy - 0.2% f.s (less than 100khz) display accuracy - 3db (100k to 1mhz) : per accuracy table on page 5 : 1 dgt. with respect to calculation from measured value (u, i, p) sum value is max. 3dgt. : 1dgt with respect to values calculated from measurements ( i, p) : max. 3dgt with respect to values calculated from measurements (u, i, p) : max. 3dgt with respect to values calculated from measurements (u, i, p) : 0.1% rdg. 1 dgt. ( 0?c to 40?c (32?f to 104?f) , f or sine wave input between 10% to 130% of u/i range ) : 1% (at 0.5hz to 1khz) , 2% (at 1khz to 10khz) , 10% (at 10khz to 100khz) v, a, w apparent / reactive power integration power factor phase angle frequency wave peak : single phase 2 wire, single phase 3 wire, 3 phase 3 wire (3v3a is possible), 3 phase 4 wire : when using 9600, 9601, 9602 (optional) voltage, current, voltage/current peak, effective/reactive/apparent power, power factor, phase, frequency, current/power integration, load rate, efficiency. when using the 9603 (optional) voltage, torque, r/min, frequency, motor output. when using the 9605 (optional) harmonic, waveform, voltage fluctuation / flicker measurement function. : at the lowest range in the dc mode of models 9600 & 9602 : 0.2% to 130% at the lowest range in the ac+dc mode of models 9600 & 9602: 0.5% to 130% at the 200ma range of model 9601: 0.5% to 130% at 0.1% to 130% of all other ranges. all range is zero suppressed at less than lower % value. valid input range for voltage, current, and power is 0.5% to 110% : 6.4 inch tft color lcd (640 480 dot) : 99999 count (except with integration) , 9999999 count (with integration) : switchable between rms (true root mean square value) a nd mean (average rectified rms indication) . when combined mode dc is selected, its not possible to switch between them. : 8 times/sec. : dc, ac + dc, ac (ac only when used in combination with 9601 or 9602 + ac clamp-on sensor) : fast (0.1 sec.), mid (0.8 sec.), slow (5.0 sec.) (time required for stabilization to within 1% when input is changed from 0% to 90%, or 100% to 10% of range.) : off / 500hz / 5khz / 300khz (-3db) for 9601, 5k / 300khz not available. : off / 200hz (-3db) : voltage / current / active power dc 5v f.s (1000v range is dc 3.333 v f.s.) : voltage / current: 1vrms f.s. (1000v range is 0.6667 vrms f.s.) : see page 5 specifications for individual input units : 64 times/sec : 0 to 9999999 tah / twh (integration time up to 10,000 hours) : -1.0000 (lead) to 0.0000 to 1.0000 (lag) -180?(lead) to 0.00?to 180.00?(lag) : max. 3ch (selection of voltage or current for arbitrary channel) : 0.5 hz to 2 mhz : auto / 50hz/ 500hz / 50 khz / 2 mhz : select either voltage or current for each unit (shows absolute value of max.) : effective value of sine wave is within effective input permi- ssible in the range measurement line measurement item display indication range display display resolution rectification method display update rate combined mode analog response time low pass filter polarity detection regulation filter analog output monitor output measurement range number of measurements measurement range measurement range number of channels effective input range measurement range measurement items effective input range [voltage/ current/ active power measurement] [integration measurement] [power factor/ phase angle measurement] [wave peak measurement] [motor output (pm) measured] 9603 (optional) external input unit required [efficiency measurement] [d/a output] [fdd] [interface] [external control] [other functions] [harmonic / flicker measurement] 9605 (optional) required [frequency measurement] general specifications
3193e6-62m-04k printed in japan all information correct as of feb.13, 2006. all specifications are subject to change without notice. head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-co m @ hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki @ hiokiusa.com distributed by shanghai representative office : 1704 shanghai times square office 93 huaihai zhong road shanghai, 200021, p.r.china tel +86-21-6391-0090/0092 fax +86-21-6391-0360 e-mail: info@ hioki.cn 7 options 9270 clamp on sensor (20a ac) 9271 clamp on sensor ( 200a ac) 9272 clamp on sensor ( 20/200a ac) 9277 universal clamp on ct (20a ac/dc) 9278 universal clamp on ct (200a ac/dc) 9279 universal clamp on ct (500a ac/dc) 9709 ac/dc current sensor (500a ac/dc) 9290 clamp on adapter (1500a ac, ratio10 :1) 9232 recording paper (10 m, 10 roll, for 9604) 3193 power hitester (main unit only) 3194 motor / harmonic hitester (main unit only) *no ce marking * options that can be installed at the factory (specify at time of order) 9600 ac/dc direct input unit 9601 ac direct input unit 9602 ac/dc clamp input unit 9603 external signal input unit (3193 only) 9603 -01 external signal input unit (3194 only) 9604 printer unit 9605 harmonic / flicker measurements unit (3193 only) * * * * clamp-on sensor (optional) specifications 9270 20a ? 20mm 5hz to 50khz 9272 20a/200a ? 46m m , 50 ? 20mm busbar 5hz to 10khz 927 9 500a ? 40mm dc to 20khz 9709 500a ? 36 mm dc to 100khz ac ac / dc to use the clamp-on sensor, be sure to order the factory option 9602 ac/dc clamp input unit. ordering information use the same input unit for a particular measurement line. install units in succession starting from channel 1. for the 9603 or 9603 -01 , only one unit can be installed. when the 9602 is selected, use the optional clamp-on sensor. 1ch 2ch 3ch 4ch 5ch 6ch pattern a 1 ? 2w ( ) 1 ? 2w ( ) 1 ? 2w ( ) 1 ? 2w ( ) 1 ? 2w ( ) 1 ? 2w ( ) pattern b 1 ? 3w / 3 ? 3w ( 2 ) 1 ? 2w ( ) 1 ? 2w ( ) 1 ? 2w ( ) 1 ? 2w ( ) pattern c 1 ? 3w / 3 ? 3w ( 2 ) 1 ? 3w / 3 ? 3w ( 2 ) 1 ? 2w ( ) 1 ? 2w ( ) pattern d 1 ? 3w / 3 ? 3w ( 2 ) 1 ? 3w / 3 ? 3w ( 2 ) 1 ? 3w / 3 ? 3w ( 2 ) pattern e 3v3a (3 ? 3w) / 3 ? 4w ( 3 ) 1 ? 2w ( ) 1 ? 2w ( ) 1 ? 2w ( ) pattern f 3v3a (3 ? 3w) / 3 ? 4w ( 3 ) 1 ? 3w / 3 ? 3w ( 2 ) 1 ? 2w ( ) pattern g 3v3a (3 ? 3w) / 3 ? 4w ( 3 ) 3v3a (3 ? 3w) / 3 ? 4w ( 3 ) measurements cannot be taken with a 3193 power hitester and 3194 motor / harmonic hitester unit only. a factory option input unit must be purchased. notes on input unit selection ( ) : 9600, 9601, 9602 can be selected. *the voltage cable is not supplied. contact your dealer when it is necessary to use the clip type leads. 9290 1500a ? 40mm 80mm-wide busbar 20hz to 4khz ct ratio 1 0 : 1 200a ? 20mm 5hz to 50khz 9277 / 9278 20 / 200a ? 20mm dc to 100khz 9277 92 71 3193 or 3194 + 9602


▲Up To Search▲   

 
Price & Availability of 3193

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X